Lintel Type : Cavity Lintels
Cavity Width : 90-105mm
Lintel Duty : Standard Duty
Thermally Broken : Yes
Birtley
Birtley 90mm ST90 Thermally Broken Cavity Lintel
£40.00 (ex VAT)
Pickup available at Tipton West Midlands
Usually ready in 4 hours
Become a trade card holder and get a discount on this item
The Birtley ST90 90mm Thermally Broken Cavity Lintel is a standard-duty lintel from Birtley's Supatherm range, designed for cavity widths of 90–105mm. Its thermally broken construction is designed to reduce heat loss at masonry openings compared with standard cavity wall lintels. Birtley states that the Supatherm range can reduce heat loss by up to 80%, helping projects work towards Part L Building Regulations and the Future Homes Standard. The ST90 is available in eight lengths from 750mm to 2100mm in Wade's current listing. It is not suitable for point loads or concrete floors.
ST90 at a Glance
Key Features
Thermally broken design
Part of Birtley's Supatherm range, designed to reduce heat loss through cavity wall lintels.
90–105mm cavity range
Designed for cavity wall construction within the manufacturer's stated cavity range.
Supports energy-efficiency objectives
Birtley states that Supatherm lintels can contribute towards meeting Part L Building Regulations and the Future Homes Standard.
65µm galvanised coating
Hot-dip galvanised coating to EN 1461 is specified as standard in Birtley's Supatherm literature.
Standard-duty option
The ST90 is the standard-duty model in the Supatherm 90mm cavity range.
No single-leaf lintel propping arrangement
Birtley identifies avoiding the propping associated with single-leaf lintels as a feature of the Supatherm range. Always follow the product-specific installation guidance.
Product Specifications
| Manufacturer | Birtley |
|---|---|
| Product reference | ST90 |
| Product range | Supatherm |
| Lintel type | Standard-duty thermally broken cavity wall lintel |
| Cavity range | 90–105mm |
| Finish | 65µm hot-dip galvanised coating to EN 1461, as stated in Birtley's Supatherm literature |
| Product standard | BS EN 845-2 |
| Published thermal performance | Psi values vary by lintel length and wall build-up; see the manufacturer's length-band data below |
| Not suitable for | Point loads or concrete floors |
Available Lengths
Wade currently lists the following eight ST90 lengths:
| Length | Product code |
|---|---|
| 750mm | ST900750 |
| 1050mm | ST901050 |
| 1200mm | ST901200 |
| 1350mm | ST901350 |
| 1500mm | ST901500 |
| 1650mm | ST901650 |
| 1950mm | ST901950 |
| 2100mm | ST902100 |
Published Thermal (Psi) Values
Birtley publishes the following Psi value bands for the ST90, grouped by lintel length:
| Lintel length band | Psi value (W/mK) |
|---|---|
| 750–1050mm | 0.098–0.057 |
| 1200–1350mm | 0.053–0.048 |
| 1500–1650mm | 0.043–0.039 |
| 1800–2100mm | 0.060–0.052 |
Thermal Performance and Building Regulations
Birtley states that the Supatherm range can reduce heat loss by up to 80% compared with standard cavity wall lintels. The range is designed to help projects address thermal bridging at window and door openings and can contribute towards meeting Part L Building Regulations and the Future Homes Standard. Actual performance depends on the lintel length, cavity, insulation and wider wall construction.
Technical Information
For detailed dimensions, declarations of performance, CAD information and project-specific thermal calculations, refer to Birtley's ST90 technical resources.
Frequently Asked Questions
What cavity size is the Birtley ST90 designed for?
Birtley specifies the ST90 for cavity widths from 90mm to 105mm.
What is the Birtley ST90?
It is a standard-duty thermally broken cavity wall lintel from Birtley's Supatherm range.
Can the ST90 be used with point loads or concrete floors?
No. Birtley states that the ST90 is not suitable for point loads or concrete floors. Seek advice on the appropriate alternative for these applications.
How much can the Supatherm range reduce heat loss?
Birtley states that Supatherm lintels can reduce heat loss by up to 80% compared with standard cavity wall lintels. Actual performance depends on the lintel and wall construction.
What are the Psi values for the ST90?
Birtley publishes Psi values by lintel length band. The figures and their calculation assumptions are shown in the thermal performance section above. Project-specific values should be checked using Birtley's PSI calculator.
What lengths are available from Wade?
The current Wade listing offers 750mm, 1050mm, 1200mm, 1350mm, 1500mm, 1650mm, 1950mm and 2100mm lengths.
Does the ST90 require the same propping as a single-leaf lintel?
Birtley identifies avoiding the propping associated with single-leaf lintels as a feature of the Supatherm range. Always follow the product-specific installation guidance.
Need Help Choosing a Thermally Broken Lintel?
Contact Wade Building Supplies for help checking the cavity size, lintel length and suitability of the ST90 for your project.
Estimate shipping
Featured Collection
More great deals at Wade
Request a Quote
Your basket is currently empty.
Start Shopping-
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Solid Wall Box Lintel
Quick view -
Cavity Lintel
Quick view Catnic CG70/100 Standard Duty 70mm Cavity Lintel From £59.00 / £49.17 (ex VAT)In stockCavity Lintel -
Cavity Lintel
Quick view Catnic CG110/100 Standard Duty 110mm Cavity Lintel From £59.00 / £49.17 (ex VAT)In stockCavity Lintel