The Birtley TF50 Standard Duty 50mm Cavity Timber Frame Lintel is designed for timber-frame wall construction with a 50–65mm cavity and a 100mm outer leaf. Manufactured from structural-grade S275JR mild steel, it features Birtley's Supergalv hot-dip galvanised coating, applied after fabrication, and expanded polystyrene (EPS) insulation. The TF50 is available in six lengths from 1050mm to 2100mm. A pinch batten must be used during installation. Check Birtley's technical information for the appropriate length, loading and installation requirements.

TF50 at a Glance

50–65mm Cavity range
100mm Outer leaf
Supergalv Hot-dip galvanised finish
6 lengths 1050mm–2100mm

Key Features

Designed for timber-frame walls

For timber-frame construction with a 50–65mm cavity and 100mm outer leaf.

Standard-duty design

A standard-duty lintel for the manufacturer's stated application. Check the published load information for the selected length.

Supergalv coating

Hot-dip galvanised after fabrication, with a 65µm coating specified by Birtley.

Structural-grade steel

Manufactured from S275JR mild steel to BS EN 10025-2.

EPS insulation

Incorporates expanded polystyrene insulation. Birtley lists the insulation with a BREEAM A+ rating.

Pinch batten required

Birtley specifies that a pinch batten must be used. Follow the manufacturer's installation details.

Product Specifications

Birtley TF50 — product details
Manufacturer Birtley
Product reference TF50
Lintel type Standard-duty timber frame cavity lintel
Cavity range 50–65mm
Outer leaf 100mm
Material S275JR mild steel to BS EN 10025-2
Finish 65µm hot-dip galvanised coating after fabrication (Supergalv), to BS EN ISO 1461
Insulation Expanded polystyrene (EPS)
Product standard BS EN 845-2:2013+A1:2016
Test standard EN 846-9:2000/2016
Fire rating stated by Birtley 60 minutes with a two-coat plaster finish
Minimum end bearing 150mm

Available Lengths

Choose from the six lengths currently stocked by Wade:

Birtley TF50 available lengths and product codes
Length Product code
1050mm TF501050
1200mm TF501200
1350mm TF501350
1500mm TF501500
1650mm TF501650
2100mm TF502100

Published Load and Profile Information

Birtley's TF50 technical data groups lintel lengths by profile size and lists an SWL/UDL load value for each range. The figures below show the manufacturer's published bands relevant to the lengths offered on this Wade listing.

Birtley TF50 published length-band data
Length band Load (kN) Weight (kg/m) Height (mm)
750–1350mm 8 3.8 108
1500–1650mm 8 4.1 128
1800–2250mm 10 5.0 178

These are Birtley's published length-band figures, not a substitute for checking the lintel against the actual opening, masonry, support and loading conditions. Refer to the manufacturer's technical data before specifying.

Installation Requirements

Birtley's TF50 product information also specifies the following installation requirements:

  • Bed the lintel fully on bricklaying mortar.
  • Use with a cavity tray on external walls.
  • Fit lintel clips at intervals of less than 600mm, with no clip more than 225mm from either end.
  • Provide a minimum end bearing of 150mm.
  • Prop lintels longer than 1200mm until the masonry is fully loaded and the mortar has matured. Use a horizontal timber spreader to avoid distorting the lintel.
  • For openings up to 2100mm, Birtley's brochure specifies a single central prop. For larger openings, use multiple props at maximum 1200mm spacing.

Follow Birtley's current installation guidance and seek technical advice where the wall build-up or site conditions differ from the manufacturer's details.

Technical Information

For detailed product, load and installation information, refer to Birtley's TF50 technical resources.

Frequently Asked Questions

What cavity size is the Birtley TF50 designed for?

The TF50 is designed for a 50–65mm cavity and a 100mm outer leaf.

Is the TF50 suitable for timber-frame construction?

Yes. It is a standard-duty lintel designed for timber-frame cavity wall construction.

What finish does the Birtley TF50 have?

It has a 65µm Supergalv hot-dip galvanised coating applied after fabrication.

Is a pinch batten required?

Yes. Birtley's product information states that a pinch batten must be used.

What is the minimum end bearing?

Birtley's product data specifies a minimum end bearing of 150mm.

Which lengths are available from Wade?

The current Wade listing offers 1050mm, 1200mm, 1350mm, 1500mm, 1650mm and 2100mm lengths.

Does the TF50 need propping during installation?

Birtley specifies that lintels longer than 1200mm must be propped until the masonry is fully loaded and cured. Follow the manufacturer's installation guidance.

Is the stated fire rating unconditional?

No. Birtley states a 60-minute fire rating with a two-coat plaster finish. The stated rating should not be assumed for every wall or finish arrangement.

Need Help Choosing a Timber Frame Lintel?

Contact Wade Building Supplies for help checking cavity dimensions, lintel length and installation requirements for your project.

Contact Wade Building Supplies
Estimate shipping
Length
Birtley 50mm Cavity Timber Frame Lintel STD Duty by Birtley

Request a Quote

Get a personalised quote for your bulk order for Birtley TF50 50mm Cavity Timber Frame Lintel STD Duty. Fill out the form below and we'll get back to you within 24 hours.