Lintel Type : Cavity Lintels
Cavity Width : 90-105mm
Lintel Duty : Standard Duty
Thermally Broken : Yes
Catnic
Catnic TS90/100 Standard Duty Thermally Broken Lintel
£58.00 (ex VAT)
Pickup available at Tipton West Midlands
Usually ready in 4 hours
Become a trade card holder and get a discount on this item
The Catnic TS90/100 Standard Duty Thermally Broken Cavity Lintel is designed for masonry cavity walls with a 90–105mm cavity, a 100–115mm inner leaf and a 100–102mm outer leaf. Its thermally broken steel profile and integral insulation help reduce heat loss around structural openings. The TS90/100 also incorporates an integral plaster key and Catnic's Duplex corrosion protection finish. Our listed sizes range from 750mm to 2100mm, with published safe working loads of 15kN, 18kN or 20kN depending on length.
Catnic TS90/100 key features
Thermally broken profile
Designed with a complete thermal break to reduce heat transfer through the steel lintel.
90–105mm cavity walls
Suitable for a 100–115mm inner masonry leaf and a 100–102mm outer leaf.
Standard duty loading
Designed for specified masonry, timber floor and roof loads within Catnic's published capacity.
Integral insulation
Fully insulated to help reduce thermal bridging around the opening.
Integral plaster key
Provides a built-in key to assist plaster finishing without requiring a separate mesh key.
Duplex corrosion protection
Galvanised steel protected by Catnic's black polyester powder coating.
Dimensions and specification
| Manufacturer | Catnic |
|---|---|
| Product code | TS90/100 |
| Lintel type | Standard duty thermally broken cavity wall lintel |
| Cavity width | 90–105mm |
| Inner leaf | 100–115mm |
| Outer leaf | 100–102mm |
| Lengths listed | 750–2100mm (nine sizes) |
| Manufacturer's length range | 750–3600mm |
| Nominal height | 153mm or 202mm for the sizes listed |
| Nominal end bearing | 150mm at each end |
| Safe working load | 15–20kN for the sizes listed |
| Thermal break | Complete thermal break with integral insulation |
| Plaster key | Integral |
| Separate DPC tray | Required by Catnic |
| Finish | Galvanised steel with black powder coating |
Catnic TS90/100 sizes and safe working loads
The TS90/100 has different safe working loads, heights and weights depending on length. The table below covers the nine sizes currently listed on this page.
| Length | SWL | Weight | Height |
|---|---|---|---|
| 750mm | 15kN | 5.95kg | 153mm |
| 900mm | 15kN | 7.14kg | 153mm |
| 1050mm | 15kN | 8.33kg | 153mm |
| 1200mm | 15kN | 9.52kg | 153mm |
| 1350mm | 15kN | 10.71kg | 153mm |
| 1500mm | 15kN | 11.90kg | 153mm |
| 1650mm | 18kN | 19.45kg | 202mm |
| 1800mm | 18kN | 21.22kg | 202mm |
| 2100mm | 20kN | 24.76kg | 202mm |
Thermal performance and cavity wall construction
The TS90/100 uses a thermally broken profile with integral insulation to minimise the transfer of heat through the steel lintel. Catnic publishes independently verified Psi values of 0.02–0.05W/mK for its thermally broken lintel system, supporting improved thermal performance around window and door openings.
Its open-back design allows masonry to be built continuously on both leaves and can accommodate fair-faced inner leaf masonry where specified.
Damp-proof course requirements
A separate DPC tray is required for the Catnic TS90/100. Follow Catnic's current installation guidance for correct damp-proofing, drainage and cavity-wall detailing.
Choosing and installing the correct TS90/100
Catnic's published loading figures use nominal 150mm end bearings at each end. As a general starting point, allow 300mm in addition to the clear structural opening width.
For example, a 1200mm opening would normally require a 1500mm lintel, providing 150mm bearing at each end. Confirm the selected lintel's safe working load and the project structural design before installation.
Follow Catnic's current guidance for supporting masonry, temporary propping where required, restraint, insulation continuity and separate DPC installation.
Related Catnic cavity lintels
For a conventional standard duty lintel without the same thermally broken profile, compare our Catnic CG90/100 Standard Duty Cavity Lintel.
For heavier-duty masonry cavity wall requirements, explore our Catnic CH90/100 Heavy Duty Cavity Lintel or Catnic CX90/100 Extra Heavy Duty Cavity Lintel. Check the loading and thermal requirements before selecting an alternative.
Browse our cavity lintel range for other wall configurations and specifications.
Technical downloads
Frequently asked questions
What is the Catnic TS90/100 used for?
The TS90/100 is a standard duty thermally broken steel lintel for masonry cavity walls with a 90–105mm cavity, a 100–115mm inner leaf and a 100–102mm outer leaf.
Is the Catnic TS90/100 thermally broken?
Yes. It features a complete thermal break with integral insulation to help reduce heat transfer through the lintel.
Does the TS90/100 require a separate DPC?
Yes. Catnic specifies that a separate DPC tray is required for the TS90/100.
What lengths of TS90/100 are available?
Our current range includes nine listed lengths from 750mm to 2100mm. Choose the size required from the options above.
What is the safe working load of a TS90/100 lintel?
For the sizes listed here, Catnic specifies 15kN at 750–1500mm, 18kN at 1650–1800mm and 20kN at 2100mm. Refer to the loading table for the corresponding heights and weights.
Does the TS90/100 have an integral plaster key?
Yes. Catnic specifies an integral plaster key designed to assist plaster finishing.
Estimate shipping
Featured Collection
More great deals at Wade
Request a Quote
Your basket is currently empty.
Start Shopping-
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Solid Wall Box Lintel
Quick view -
Cavity Lintel
Quick view Catnic CG70/100 Standard Duty 70mm Cavity Lintel From £59.00 / £49.17 (ex VAT)In stockCavity Lintel -
Cavity Lintel
Quick view Catnic CG110/100 Standard Duty 110mm Cavity Lintel From £59.00 / £49.17 (ex VAT)In stockCavity Lintel