Catnic

Catnic TS90/100 Standard Duty Thermally Broken Lintel

£58.00
Cavity Lintel

£58.00 (ex VAT)

Length

Pickup available at Tipton West Midlands

Usually ready in 4 hours

Become a trade card holder and get a discount on this item

Create an account or Log in

Request a Bulk Quote

The Catnic TS90/100 Standard Duty Thermally Broken Cavity Lintel is designed for masonry cavity walls with a 90–105mm cavity, a 100–115mm inner leaf and a 100–102mm outer leaf. Its thermally broken steel profile and integral insulation help reduce heat loss around structural openings. The TS90/100 also incorporates an integral plaster key and Catnic's Duplex corrosion protection finish. Our listed sizes range from 750mm to 2100mm, with published safe working loads of 15kN, 18kN or 20kN depending on length.

Catnic TS90/100 key features

Thermally broken profile

Designed with a complete thermal break to reduce heat transfer through the steel lintel.

90–105mm cavity walls

Suitable for a 100–115mm inner masonry leaf and a 100–102mm outer leaf.

Standard duty loading

Designed for specified masonry, timber floor and roof loads within Catnic's published capacity.

Integral insulation

Fully insulated to help reduce thermal bridging around the opening.

Integral plaster key

Provides a built-in key to assist plaster finishing without requiring a separate mesh key.

Duplex corrosion protection

Galvanised steel protected by Catnic's black polyester powder coating.

Dimensions and specification

Catnic TS90/100 technical specifications
Manufacturer Catnic
Product code TS90/100
Lintel type Standard duty thermally broken cavity wall lintel
Cavity width 90–105mm
Inner leaf 100–115mm
Outer leaf 100–102mm
Lengths listed 750–2100mm (nine sizes)
Manufacturer's length range 750–3600mm
Nominal height 153mm or 202mm for the sizes listed
Nominal end bearing 150mm at each end
Safe working load 15–20kN for the sizes listed
Thermal break Complete thermal break with integral insulation
Plaster key Integral
Separate DPC tray Required by Catnic
Finish Galvanised steel with black powder coating

Catnic TS90/100 sizes and safe working loads

The TS90/100 has different safe working loads, heights and weights depending on length. The table below covers the nine sizes currently listed on this page.

TS90/100 length, safe working load, weight and height
Length SWL Weight Height
750mm 15kN 5.95kg 153mm
900mm 15kN 7.14kg 153mm
1050mm 15kN 8.33kg 153mm
1200mm 15kN 9.52kg 153mm
1350mm 15kN 10.71kg 153mm
1500mm 15kN 11.90kg 153mm
1650mm 18kN 19.45kg 202mm
1800mm 18kN 21.22kg 202mm
2100mm 20kN 24.76kg 202mm

Thermal performance and cavity wall construction

The TS90/100 uses a thermally broken profile with integral insulation to minimise the transfer of heat through the steel lintel. Catnic publishes independently verified Psi values of 0.02–0.05W/mK for its thermally broken lintel system, supporting improved thermal performance around window and door openings.

Its open-back design allows masonry to be built continuously on both leaves and can accommodate fair-faced inner leaf masonry where specified.

Damp-proof course requirements

A separate DPC tray is required for the Catnic TS90/100. Follow Catnic's current installation guidance for correct damp-proofing, drainage and cavity-wall detailing.

Choosing and installing the correct TS90/100

Catnic's published loading figures use nominal 150mm end bearings at each end. As a general starting point, allow 300mm in addition to the clear structural opening width.

For example, a 1200mm opening would normally require a 1500mm lintel, providing 150mm bearing at each end. Confirm the selected lintel's safe working load and the project structural design before installation.

Follow Catnic's current guidance for supporting masonry, temporary propping where required, restraint, insulation continuity and separate DPC installation.

For a conventional standard duty lintel without the same thermally broken profile, compare our Catnic CG90/100 Standard Duty Cavity Lintel.

For heavier-duty masonry cavity wall requirements, explore our Catnic CH90/100 Heavy Duty Cavity Lintel or Catnic CX90/100 Extra Heavy Duty Cavity Lintel. Check the loading and thermal requirements before selecting an alternative.

Browse our cavity lintel range for other wall configurations and specifications.

Technical downloads

Frequently asked questions

What is the Catnic TS90/100 used for?

The TS90/100 is a standard duty thermally broken steel lintel for masonry cavity walls with a 90–105mm cavity, a 100–115mm inner leaf and a 100–102mm outer leaf.

Is the Catnic TS90/100 thermally broken?

Yes. It features a complete thermal break with integral insulation to help reduce heat transfer through the lintel.

Does the TS90/100 require a separate DPC?

Yes. Catnic specifies that a separate DPC tray is required for the TS90/100.

What lengths of TS90/100 are available?

Our current range includes nine listed lengths from 750mm to 2100mm. Choose the size required from the options above.

What is the safe working load of a TS90/100 lintel?

For the sizes listed here, Catnic specifies 15kN at 750–1500mm, 18kN at 1650–1800mm and 20kN at 2100mm. Refer to the loading table for the corresponding heights and weights.

Does the TS90/100 have an integral plaster key?

Yes. Catnic specifies an integral plaster key designed to assist plaster finishing.

Estimate shipping
Length
Catnic TS90/100 90-105mm Thermally Broken Cavity Lintel by Catnic

Request a Quote

Get a personalised quote for your bulk order for Catnic TS90/100 Standard Duty Thermally Broken Lintel. Fill out the form below and we'll get back to you within 24 hours.