The Catnic CCS 100mm single-leaf lintel is a standard-duty C-section steel lintel designed to support masonry loads above openings in suitable 100–102mm single-leaf walls. Manufactured from galvanised steel with Catnic's black Duplex corrosion protection finish, the CCS range offers lengths from 750mm to 4800mm, with safe working loads of 15kN or 20kN depending on length.
Catnic CCS key features
Single-leaf masonry
Designed for suitable 100–102mm single-leaf brick or block wall construction.
Standard-duty loading
Safe working loads of 15kN for shorter lengths and 20kN for longer lengths, subject to Catnic's specified loading conditions.
C-section profile
A channel-shaped steel section designed to support masonry above structural openings.
Duplex corrosion protection
Galvanised steel with Catnic's black polyester powder coating for additional corrosion resistance.
Range of lengths
Manufactured in lengths from 750mm to 4800mm, with the available Wade options selectable above.
Masonry and timber floor loads
Designed for specified masonry and timber floor loading applications where the calculated load is within the lintel's rated capacity.
Dimensions and specification
| Manufacturer | Catnic |
|---|---|
| Product code | CCS |
| Lintel type | Single-leaf steel C-section lintel |
| Duty | Standard duty |
| Wall thickness | 100–102mm |
| Cavity | Not applicable |
| Manufacturer's length range | 750–4800mm |
| Nominal end bearing | 150mm at each end |
| Nominal height | 154mm (750–1800mm); 229mm (1950–4800mm) |
| Safe working load | 15–20kN, depending on length |
| Finish | Galvanised steel with black powder coating |
Catnic CCS sizes and safe working loads
Catnic specifies two loading categories within the CCS range. The safe working load depends on the length of the lintel.
| Lintel length | Safe working load |
|---|---|
| 750–1800mm | 15kN |
| 1950–4800mm | 20kN |
Where to use a Catnic CCS lintel
The CCS is designed for 100–102mm single-leaf masonry construction, where a C-section lintel is specified to support suitable masonry or timber floor loads above an opening.
The Catnic CCS lintel is suitable for both internal and external single-leaf masonry applications, although it is predominantly used externally. Installation must meet Catnic's specified wall construction, loading and support requirements.
Unlike a combined cavity-wall lintel, the CCS supports a single leaf of masonry. Wall construction, load requirements and the chosen length must all be checked against the manufacturer's specifications before installation.
Choosing the correct CCS lintel length
Catnic specifies nominal 150mm end bearings. The lintel length is therefore normally calculated by adding 300mm to the structural opening width, allowing 150mm bearing at each end.
For example, a 1200mm structural opening would normally require a 1500mm lintel. The selected length must also have a sufficient safe working load for the intended construction.
Installation and support requirements
Catnic CCS lintels must be suitably propped and laterally restrained during construction. To achieve the published loading figures, the lintel must be fully built into the brickwork or blockwork as specified by Catnic.
Related single-leaf lintels
For a different profile, Wade also supplies the Catnic ANG 100mm single-leaf angle lintel.
Browse our single-leaf lintel collection for other available models and lengths.
Technical downloads
Frequently asked questions
What wall thickness is the Catnic CCS designed for?
The Catnic CCS is designed for 100–102mm single-leaf masonry construction. It is not a combined cavity-wall lintel.
Does the Catnic CCS lintel have an integral plaster key?
No. The Catnic CCS lintel does not have an integral plaster key.
What is the safe working load of a Catnic CCS lintel?
CCS lintels from 750mm to 1800mm have a published safe working load of 15kN. Lengths from 1950mm to 4800mm have a published safe working load of 20kN. These ratings are subject to Catnic's specified installation and loading conditions.
Does a Catnic CCS lintel require propping?
Yes. Catnic specifies that CCS lintels must be suitably propped and laterally restrained during construction.
How much end bearing does a CCS lintel need?
Catnic specifies nominal 150mm end bearings at each end. Check the structural opening, the required lintel length and the applicable loading requirements before installation.
Estimate shipping
Featured Collection
More great deals at Wade
Request a Quote
Your basket is currently empty.
Start Shopping-
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Solid Wall Box Lintel
Quick view -
Cavity Lintel
Quick view Catnic CG70/100 Standard Duty 70mm Cavity Lintel From £59.00 / £49.17 (ex VAT)In stockCavity Lintel -
Cavity Lintel
Quick view Catnic CG110/100 Standard Duty 110mm Cavity Lintel From £59.00 / £49.17 (ex VAT)In stockCavity Lintel