Lintel Type : Cavity Lintels
Cavity Width : 130-145mm
Lintel Duty : Extra Heavy Duty
Thermally Broken : No
Wide Inner Leaf? No
Catnic
Catnic CX130/100 Extra Heavy Duty 130mm Cavity Lintel
£118.33 (ex VAT)
Pickup available at Tipton West Midlands
Usually ready in 4 hours
Become a trade card holder and get a discount on this item
The Catnic CX130/100 Extra Heavy Duty 130mm Cavity Lintel is designed for high-load masonry cavity walls with a 130–145mm cavity, a 100–115mm inner leaf and a 100–102mm outer leaf. Its open-back steel profile supports specified masonry, floor and roof loads, while continuous insulation, an integral plaster key and built-in DPC provide practical construction benefits. We supply 19 lengths from 900mm to 4200mm, with safe working loads ranging from 32kN to 60kN depending on length.
Catnic CX130/100 key features
Extra heavy duty loading
Designed for demanding cavity wall openings, with safe working loads up to 60kN depending on length.
130–145mm cavity walls
Suitable for a 100–115mm inner masonry leaf and a 100–102mm outer leaf.
Open-back profile
Allows masonry to be built up continuously on both leaves and accommodates fair-faced inner leaf masonry.
Built-in DPC
Incorporates a damp-proof course. Additional DPC may be required depending on installation and exposure conditions.
Integral insulation and plaster key
Continuous insulation helps reduce thermal bridging, while the integral plaster key assists plaster finishing.
Duplex corrosion protection
Manufactured from galvanised steel with Catnic's protective black polyester powder coating.
Dimensions and specification
| Manufacturer | Catnic |
|---|---|
| Product code | CX130/100 |
| Lintel type | Extra heavy duty cavity wall lintel |
| Cavity width | 130–145mm |
| Inner leaf | 100–115mm |
| Outer leaf | 100–102mm |
| Available lengths | 900–4200mm, 19 sizes |
| Nominal section height | 232mm |
| Nominal end bearings | 150mm at each end |
| Safe working load | 32–60kN, depending on length |
| Built-in DPC | Yes. Additional DPC may be required in some situations. |
| Plaster key | Integral |
| Insulation | Continuous integral insulation |
| Finish | Galvanised steel with black powder coating |
Catnic CX130/100 sizes and safe working loads
The CX130/100's safe working load and nominal weight vary according to length. The table below covers all 19 sizes we supply, using Catnic's current technical specifications.
| Length | Safe working load | Nominal weight |
|---|---|---|
| 900mm | 60kN | 16.04kg |
| 1050mm | 60kN | 18.71kg |
| 1200mm | 60kN | 21.38kg |
| 1350mm | 60kN | 24.06kg |
| 1500mm | 60kN | 26.73kg |
| 1650mm | 60kN | 29.40kg |
| 1800mm | 60kN | 32.08kg |
| 1950mm | 60kN | 34.45kg |
| 2100mm | 60kN | 37.42kg |
| 2250mm | 60kN | 40.10kg |
| 2400mm | 60kN | 42.77kg |
| 2550mm | 60kN | 45.44kg |
| 2700mm | 60kN | 48.11kg |
| 2850mm | 55kN | 50.79kg |
| 3000mm | 55kN | 53.46kg |
| 3300mm | 50kN | 70.75kg |
| 3600mm | 50kN | 77.18kg |
| 3900mm | 50kN | 83.62kg |
| 4200mm | 32kN | 90.05kg |
Where to use a Catnic CX130/100 lintel
The CX130/100 is intended for extra heavy duty masonry cavity-wall construction with a 130–145mm cavity. It supports specified masonry, timber floor and roof loads, including suitable concrete floor and attic truss loading arrangements where the structural design and manufacturer guidance permit.
The open-back profile allows masonry to be built up continuously on both leaves and is suitable for fair-faced inner leaf masonry.
Choosing the correct CX130/100 length
Catnic's published loading figures use nominal 150mm end bearings at each end. As a general starting point, add 300mm to the clear structural opening width to allow these bearings.
For example, a 1200mm structural opening would normally require a 1500mm lintel, with 150mm bearing at each end. The selected lintel must also have sufficient safe working load for the proposed construction.
Installation and support requirements
Both masonry leaves should be raised together, and the supporting wall construction must provide suitable end bearings. Follow Catnic's guidance for temporary propping, load transfer and lateral restraint during construction.
For concrete floor applications using Catnic CH and CX open-back lintels, build the blockwork tightly against the lintel's inner vertical face. Add a mortar joint at the top of the blockwork so floor units distribute their load evenly across the inner flange.
Related Catnic cavity lintels
For lower loading requirements with the same cavity dimensions, compare our Catnic CH130/100 Heavy Duty Cavity Lintel or Catnic CG130/100 Standard Duty Cavity Lintel.
For extra heavy duty construction with a wider cavity, we also supply the Catnic CX150/100 Extra Heavy Duty Cavity Lintel.
Browse our cavity lintel range and Catnic lintels for other sizes and loading requirements.
Technical downloads
Frequently asked questions
What cavity width is the Catnic CX130/100 designed for?
The CX130/100 is designed for 130–145mm cavities, with a 100–115mm inner masonry leaf and a 100–102mm outer leaf.
What lengths of Catnic CX130/100 do you supply?
We offer 19 lengths from 900mm to 4200mm. Choose your required size from the options above and check its safe working load before ordering.
What is the safe working load of CX130/100?
Catnic specifies 60kN for lengths from 900mm to 2700mm, 55kN at 2850–3000mm, 50kN at 3300–3900mm and 32kN from 4200mm upwards, subject to the manufacturer's loading conditions.
Does the CX130/100 have a built-in DPC?
Yes. The CX130/100 incorporates a built-in damp-proof course. Additional DPC may be required depending on installation and exposure conditions.
Does the CX130/100 include insulation and a plaster key?
Yes. The CX130/100 includes continuous insulation and an integral plaster key.
Can the CX130/100 support concrete floors?
Catnic provides installation guidance for CH and CX open-back lintels supporting concrete floors. Build the blockwork tightly against the lintel's inner vertical face and provide a mortar joint at the top to distribute loading evenly across the inner flange. The structural loads must also be checked.
How much end bearing does a CX130/100 require?
Catnic's published safe working loads use nominal 150mm end bearings at each end. Confirm the selected length and load capacity for your structural opening.
Estimate shipping
Featured Collection
More great deals at Wade
Request a Quote
Your basket is currently empty.
Start Shopping-
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Solid Wall Box Lintel
Quick view -
Cavity Lintel
Quick view Catnic CG70/100 Standard Duty 70mm Cavity Lintel From £59.00 / £49.17 (ex VAT)In stockCavity Lintel -
Cavity Lintel
Quick view Catnic CG110/100 Standard Duty 110mm Cavity Lintel From £59.00 / £49.17 (ex VAT)In stockCavity Lintel