Lintel Type : Timber Frame Lintels
Cavity Width : 70-85mm
Lintel Duty : Standard Duty
Catnic
Catnic CTF7 Standard Duty 70mm Timber Frame Lintel
£24.16 (ex VAT)
Pickup available at Tipton West Midlands
Usually ready in 4 hours
Become a trade card holder and get a discount on this item
The Catnic CTF7 Standard Duty 70mm Timber Frame Lintel is designed to support the external masonry leaf above openings in timber-frame construction with a 70–85mm cavity and a 100–102mm outer brick or block leaf. Its steel profile allows differential vertical movement between the timber frame and the masonry, while its built-in DPC and Duplex corrosion protection help manage moisture. We supply 20 lengths from 900mm to 4800mm, with safe working loads of 5kN, 7kN, 9kN or 10kN depending on length.
Catnic CTF7 key features
Timber-frame construction
Designed to support the external masonry leaf independently of the timber-frame structure.
70–85mm cavity width
Suitable for timber-frame walls with a 100–102mm outer masonry leaf.
Differential movement
The lintel profile allows vertical movement between the timber frame and its external masonry facing.
Standard duty loading
Provides published safe working loads from 5kN to 10kN for the supported masonry leaf, depending on length.
Built-in DPC
Incorporates a damp-proof course. Additional DPC may be required in some installation or exposure conditions.
Duplex corrosion protection
Manufactured from galvanised steel with Catnic's protective black polyester powder coating.
Dimensions and specification
| Manufacturer | Catnic |
|---|---|
| Product code | CTF7 |
| Lintel type | Standard duty timber-frame lintel |
| Wall construction | Timber frame with external masonry leaf |
| Cavity width | 70–85mm |
| Outer masonry leaf | 100–102mm |
| Inner structure | Timber frame |
| Available lengths | 900–4800mm, 20 sizes |
| Manufacturer's length range | 750–4800mm |
| Nominal section height | 145mm, 187mm or 261mm, depending on length |
| Nominal end bearings | 150mm at each end |
| Safe working load | 5–10kN, depending on length |
| Built-in DPC | Yes. Additional DPC may be required in some situations. |
| Restraint clips | Supplied; installation required |
| Timber batten | Required during construction; not supplied |
| Finish | Galvanised steel with black polyester powder coating |
Catnic CTF7 sizes and safe working loads
The safe working load, nominal height and weight of the CTF7 vary with length. The table below covers all 20 sizes we supply.
| Length | SWL | Weight | Height |
|---|---|---|---|
| 900mm | 5kN | 3.02kg | 145mm |
| 1050mm | 5kN | 3.52kg | 145mm |
| 1200mm | 5kN | 4.02kg | 145mm |
| 1350mm | 5kN | 4.52kg | 145mm |
| 1500mm | 5kN | 5.03kg | 145mm |
| 1650mm | 7kN | 4.02kg | 145mm |
| 1800mm | 7kN | 7.54kg | 145mm |
| 1950mm | 7kN | 9.18kg | 187mm |
| 2100mm | 7kN | 9.89kg | 187mm |
| 2250mm | 7kN | 10.60kg | 187mm |
| 2400mm | 7kN | 11.30kg | 187mm |
| 2550mm | 9kN | 18.67kg | 261mm |
| 2700mm | 9kN | 19.76kg | 261mm |
| 2850mm | 9kN | 20.86kg | 261mm |
| 3000mm | 9kN | 21.96kg | 261mm |
| 3300mm | 9kN | 24.16kg | 261mm |
| 3600mm | 9kN | 26.35kg | 261mm |
| 3900mm | 10kN | 35.41kg | 261mm |
| 4200mm | 10kN | 38.14kg | 261mm |
| 4800mm | 10kN | 43.58kg | 261mm |
Where to use a Catnic CTF7 timber frame lintel
The CTF7 is designed for openings in timber-frame construction where a 100–102mm external brick or block leaf requires support across a 70–85mm cavity. Its profile accommodates differential vertical movement between the timber frame and the masonry facing.
Unlike a combined masonry cavity-wall lintel, the CTF7 supports the outer masonry leaf independently of the structural timber frame. Confirm the wall construction and cavity width before ordering.
Choosing the correct CTF7 length
Catnic's published loading figures use nominal 150mm end bearings at each end. As a general starting point, add 300mm to the clear structural opening width to allow for these bearings.
For example, a 1200mm structural opening would normally require a 1500mm lintel, allowing 150mm bearing on either side. The selected lintel must also provide sufficient safe working load for the masonry above.
Installation, propping and restraint clips
CTF7 timber-frame lintels must be suitably propped during construction and secured to the timber frame using Catnic's supplied restraint clips and a timber batten. The timber batten is not supplied with the lintel.
The restraint arrangement helps prevent the lintel twisting during construction while allowing the differential movement required between the timber frame and masonry outer leaf. Follow Catnic's installation guidance for clip positioning and fixing.
How many restraint clips are required?
| Lintel length | Number of clips |
|---|---|
| Up to 1800mm | 3 |
| 1950–3000mm | 5 |
| 3300–4200mm | 7 |
| 4575–4800mm | 9 |
Related Catnic timber frame lintels
For a narrower cavity, compare our Catnic CTF5 Standard Duty Timber Frame Lintel, designed for 50–65mm cavities.
For a wider cavity, we also supply the Catnic CTF9 Standard Duty Timber Frame Lintel, designed for 90–105mm cavities.
Browse our Catnic lintel range for further options and specifications.
Technical information
Frequently asked questions
What is the Catnic CTF7 used for?
The CTF7 is a standard duty timber-frame lintel designed to support an external masonry leaf above openings in timber-frame walls with a 70–85mm cavity.
What cavity width is the Catnic CTF7 designed for?
The CTF7 is designed for 70–85mm cavities with a 100–102mm external masonry leaf. The inner structure is timber framed.
What lengths of Catnic CTF7 do you supply?
We offer 20 lengths from 900mm to 4800mm. Choose your required size from the options above and check its safe working load before ordering.
What safe working load can a CTF7 support?
Catnic specifies 5kN for 750–1500mm lengths, 7kN for 1650–2400mm, 9kN for 2550–3600mm and 10kN for 3900–4800mm, subject to the manufacturer's loading conditions.
Are restraint clips supplied with the CTF7?
Yes. Catnic supplies restraint clips with the lintel. They must be fitted during installation, together with a suitable timber batten, which is not supplied.
Does the CTF7 require temporary propping?
Yes. The lintel must be suitably propped during construction. Temporary props can be removed once the mortar has cured and the wall ties have become effective, in accordance with Catnic's guidance.
Does the CTF7 have a built-in DPC?
Yes. The CTF7 incorporates a built-in damp-proof course. Additional damp-proofing may be required in some installation or exposure conditions.
Can the CTF7 support timber floor or roof loads?
The CTF7 is designed to support the external masonry leaf. Loads from the timber-frame superstructure, including structural floor and roof loads, must be supported and designed separately.
Estimate shipping
Featured Collection
More great deals at Wade
Request a Quote
Your basket is currently empty.
Start Shopping-
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Cavity Lintel
Quick view -
Solid Wall Box Lintel
Quick view -
Cavity Lintel
Quick view Catnic CG70/100 Standard Duty 70mm Cavity Lintel From £59.00 / £49.17 (ex VAT)In stockCavity Lintel -
Cavity Lintel
Quick view Catnic CG110/100 Standard Duty 110mm Cavity Lintel From £59.00 / £49.17 (ex VAT)In stockCavity Lintel