The Catnic TS150/100 Standard Duty Thermally Broken Cavity Lintel is designed for masonry cavity walls with a 150–165mm cavity, a 100–115mm inner leaf and a 100–102mm outer leaf. Its fully insulated, open-back steel profile incorporates a complete thermal break to reduce heat transfer between the masonry leaves. We supply eight lengths from 750mm to 2100mm, with safe working loads of 15kN, 18kN or 20kN depending on length.

Catnic TS150/100 key features

Complete thermal break

Separates the inner and outer steel sections to help reduce thermal bridging around window and door openings.

Standard duty loading

Designed for specified masonry, timber floor and roof loads, with safe working loads up to 20kN across the lengths we supply.

150–165mm cavity walls

Suitable for a 100–115mm inner masonry leaf and a 100–102mm outer leaf.

Integral insulation

Fully insulated construction helps reduce heat loss through the lintel and improve thermal performance at the wall opening.

Open-back profile

Allows masonry to be built continuously on both leaves and accommodates fair-faced inner leaf masonry.

Plaster key and protective finish

Includes an integral plaster key and Catnic's Duplex corrosion protection with black polyester powder coating.

Dimensions and specification

Catnic TS150/100 technical specifications
Manufacturer Catnic
Product code TS150/100
Lintel type Standard duty thermally broken cavity wall lintel
Cavity width 150–165mm
Inner masonry leaf 100–115mm
Outer masonry leaf 100–102mm
Lengths we supply 750, 900, 1050, 1200, 1350, 1650, 1950 and 2100mm
Nominal section height 153mm or 202mm, depending on length
Nominal end bearings 150mm at each end
Safe working load 15–20kN across our available lengths
Thermal break Complete, with integral insulation
Plaster key Integral
Damp-proofing Separate DPC tray required
Finish Duplex corrosion protection with black polyester powder coating

Catnic TS150/100 lengths and safe working loads

The TS150/100's safe working load, nominal weight and section height vary by length. The table below covers all eight sizes we supply, using Catnic's published specifications.

TS150/100 lengths, loading capacities, nominal weights and heights
Length SWL Weight Height
750mm 15kN 6.16kg 153mm
900mm 15kN 7.39kg 153mm
1050mm 15kN 8.62kg 153mm
1200mm 15kN 9.85kg 153mm
1350mm 15kN 11.08kg 153mm
1650mm 18kN 20.06kg 202mm
1950mm 20kN 23.71kg 202mm
2100mm 20kN 25.54kg 202mm

How does the TS150/100 reduce thermal bridging?

Conventional steel cavity lintels can conduct heat between the inner and outer masonry leaves. The Catnic TS150/100 incorporates a complete thermal break between its steel sections, together with integral insulation, to reduce heat transfer around the opening.

Catnic reports Psi values of 0.02–0.05 W/mK for its thermally broken lintel range. The precise performance achieved depends on the wall construction, cavity insulation and junction detailing.

The open-back profile also permits masonry to be built continuously on both leaves and is suitable for fair-faced inner leaf masonry.

Where to use a Catnic TS150/100 lintel

The TS150/100 is intended for standard duty masonry cavity walls with a 150–165mm cavity. It is designed for specified masonry, timber floor and roof loading applications where the chosen length provides sufficient safe working load.

Choosing the correct length

Catnic's published loading figures assume nominal 150mm end bearings at each end. As a general starting point, allow 300mm beyond the clear structural opening to accommodate these bearings.

For example, a 900mm clear structural opening would normally require a 1200mm lintel, providing 150mm bearing at each end. The selected lintel must also have sufficient load capacity for the proposed construction.

Installation and damp-proofing requirements

Check the cavity width, masonry leaf dimensions, end bearings and specified loads before installation. Follow Catnic's current instructions for temporary support, restraint and load transfer.

The published safe working loads do not automatically establish suitability for every concentrated loading, floor or roof arrangement. Follow the project structural design and manufacturer's installation instructions.

For a narrower cavity, compare our thermally broken lintel range, including the Catnic TS90/100 and TS110/100 models.

If a complete thermal break is not required, we also supply the Catnic CG150/100 Standard Duty Cavity Lintel for 150–165mm cavities.

Browse our Catnic lintel range for further specifications and loading options.

Technical downloads

Frequently asked questions

What is the Catnic TS150/100?

The TS150/100 is a standard duty thermally broken steel cavity lintel for masonry walls with a 150–165mm cavity. Its complete thermal break helps reduce heat transfer between the inner and outer masonry leaves.

What cavity width is the TS150/100 designed for?

It is designed for a 150–165mm cavity, with a 100–115mm inner masonry leaf and a 100–102mm outer leaf.

What lengths do you supply?

We supply eight TS150/100 lengths: 750mm, 900mm, 1050mm, 1200mm, 1350mm, 1650mm, 1950mm and 2100mm.

What is the safe working load of a TS150/100?

The 750–1350mm lengths we supply are rated at 15kN. The 1650mm lintel is rated at 18kN, and the 1950mm and 2100mm lengths are rated at 20kN, subject to Catnic's loading conditions.

Does the TS150/100 need a separate DPC?

Yes. Catnic specifies a separate DPC tray for the TS150/100. This is an important installation requirement and should not be confused with the built-in DPC found on some conventional Catnic cavity lintels.

Does the TS150/100 have a plaster key?

Yes. The TS150/100 includes an integral plaster key and continuous insulation.

How much end bearing does the TS150/100 require?

Catnic's published safe working loads use nominal 150mm end bearings at each end. Confirm the length and loading capacity against the structural opening and project design.

What is the difference between the TS150/100 and TH150/100?

Both are thermally broken cavity lintels for 150–165mm cavities. The TS150/100 is the standard duty model, while the TH150/100 is designed for heavier loading requirements. Select according to the structural loads and Catnic's published specifications.

Estimate shipping
Length
Catnic TH150/1001350 150mm Cavity Part L Heavy Duty Lintel by Catnic

Request a Quote

Get a personalised quote for your bulk order for Catnic TS150/100 Standard Duty Thermally Broken Cavity Lintel. Fill out the form below and we'll get back to you within 24 hours.