{"product_id":"catnic-single-leaf-ccs-lintel-100mm","title":"Catnic CCS 100mm Single Leaf C-Section Lintel","description":"\u003cdiv class=\"wbs-product\"\u003e\n\n  \u003cdiv class=\"wbs-product-intro\"\u003e\n    \u003cp\u003eThe \u003cstrong\u003eCatnic CCS 100mm single-leaf lintel\u003c\/strong\u003e is a standard-duty C-section steel lintel designed to support masonry loads above openings in suitable 100–102mm single-leaf walls. Manufactured from galvanised steel with Catnic's black Duplex corrosion protection finish, the CCS range offers lengths from 750mm to 4800mm, with safe working loads of 15kN or 20kN depending on length.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003csection class=\"wbs-product-section\" aria-labelledby=\"ccs-features\"\u003e\n    \u003ch2 id=\"ccs-features\"\u003eCatnic CCS key features\u003c\/h2\u003e\n\n    \u003cdiv class=\"wbs-product-feature-grid\"\u003e\n      \u003cdiv class=\"wbs-product-feature\"\u003e\n        \u003ch3\u003eSingle-leaf masonry\u003c\/h3\u003e\n        \u003cp\u003eDesigned for suitable 100–102mm single-leaf brick or block wall construction.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"wbs-product-feature\"\u003e\n        \u003ch3\u003eStandard-duty loading\u003c\/h3\u003e\n        \u003cp\u003eSafe working loads of 15kN for shorter lengths and 20kN for longer lengths, subject to Catnic's specified loading conditions.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"wbs-product-feature\"\u003e\n        \u003ch3\u003eC-section profile\u003c\/h3\u003e\n        \u003cp\u003eA channel-shaped steel section designed to support masonry above structural openings.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"wbs-product-feature\"\u003e\n        \u003ch3\u003eDuplex corrosion protection\u003c\/h3\u003e\n        \u003cp\u003eGalvanised steel with Catnic's black polyester powder coating for additional corrosion resistance.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"wbs-product-feature\"\u003e\n        \u003ch3\u003eRange of lengths\u003c\/h3\u003e\n        \u003cp\u003eManufactured in lengths from 750mm to 4800mm, with the available Wade options selectable above.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"wbs-product-feature\"\u003e\n        \u003ch3\u003eMasonry and timber floor loads\u003c\/h3\u003e\n        \u003cp\u003eDesigned for specified masonry and timber floor loading applications where the calculated load is within the lintel's rated capacity.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"wbs-product-section\" aria-labelledby=\"ccs-specs\"\u003e\n    \u003ch2 id=\"ccs-specs\"\u003eDimensions and specification\u003c\/h2\u003e\n\n    \u003cdiv class=\"wbs-product-table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable Catnic CCS specifications\"\u003e\n      \u003ctable class=\"wbs-product-table\"\u003e\n        \u003ccaption\u003eCatnic CCS technical specifications\u003c\/caption\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n            \u003ctd\u003eCatnic\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003eProduct code\u003c\/th\u003e\n            \u003ctd\u003eCCS\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003eLintel type\u003c\/th\u003e\n            \u003ctd\u003eSingle-leaf steel C-section lintel\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003eDuty\u003c\/th\u003e\n            \u003ctd\u003eStandard duty\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003eWall thickness\u003c\/th\u003e\n            \u003ctd\u003e100–102mm\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003eCavity\u003c\/th\u003e\n            \u003ctd\u003eNot applicable\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003eManufacturer's length range\u003c\/th\u003e\n            \u003ctd\u003e750–4800mm\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003eNominal end bearing\u003c\/th\u003e\n            \u003ctd\u003e150mm at each end\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003eNominal height\u003c\/th\u003e\n            \u003ctd\u003e154mm (750–1800mm); 229mm (1950–4800mm)\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003eSafe working load\u003c\/th\u003e\n            \u003ctd\u003e15–20kN, depending on length\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"row\"\u003eFinish\u003c\/th\u003e\n            \u003ctd\u003eGalvanised steel with black powder coating\u003c\/td\u003e\n          \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"wbs-product-section\" aria-labelledby=\"ccs-loading\"\u003e\n    \u003ch2 id=\"ccs-loading\"\u003eCatnic CCS sizes and safe working loads\u003c\/h2\u003e\n\n    \u003cp\u003eCatnic specifies two loading categories within the CCS range. The safe working load depends on the length of the lintel.\u003c\/p\u003e\n\n    \u003cdiv class=\"wbs-product-table-wrap\" tabindex=\"0\" role=\"region\" aria-label=\"Catnic CCS safe working loads\"\u003e\n      \u003ctable class=\"wbs-product-table\"\u003e\n        \u003ccaption\u003eCCS lintel length and safe working load\u003c\/caption\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n            \u003cth scope=\"col\"\u003eLintel length\u003c\/th\u003e\n            \u003cth scope=\"col\"\u003eSafe working load\u003c\/th\u003e\n          \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e750–1800mm\u003c\/td\u003e\n            \u003ctd\u003e15kN\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e1950–4800mm\u003c\/td\u003e\n            \u003ctd\u003e20kN\u003c\/td\u003e\n          \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n\n    \u003caside class=\"wbs-product-notice wbs-product-notice--technical\"\u003e\n      \u003cp\u003e\u003cstrong\u003eLoading information:\u003c\/strong\u003e These safe working loads are based on uniformly distributed loading over the maximum span with nominal 150mm end bearings. The selected lintel must be suitable for the actual structural opening and calculated loads.\u003c\/p\u003e\n    \u003c\/aside\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"wbs-product-section\" aria-labelledby=\"ccs-application\"\u003e\n    \u003ch2 id=\"ccs-application\"\u003eWhere to use a Catnic CCS lintel\u003c\/h2\u003e\n\n    \u003cp\u003eThe CCS is designed for 100–102mm single-leaf masonry construction, where a C-section lintel is specified to support suitable masonry or timber floor loads above an opening.\u003c\/p\u003e\n\n    \u003cp\u003eThe Catnic CCS lintel is suitable for both internal and external single-leaf masonry applications, although it is predominantly used externally. Installation must meet Catnic's specified wall construction, loading and support requirements.\u003c\/p\u003e\n\n    \u003cp\u003eUnlike a combined cavity-wall lintel, the CCS supports a single leaf of masonry. Wall construction, load requirements and the chosen length must all be checked against the manufacturer's specifications before installation.\u003c\/p\u003e\n\n    \u003ch3\u003eChoosing the correct CCS lintel length\u003c\/h3\u003e\n\n    \u003cp\u003eCatnic specifies nominal 150mm end bearings. The lintel length is therefore normally calculated by adding 300mm to the structural opening width, allowing 150mm bearing at each end.\u003c\/p\u003e\n\n    \u003cp\u003eFor example, a 1200mm structural opening would normally require a 1500mm lintel. The selected length must also have a sufficient safe working load for the intended construction.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"wbs-product-section\" aria-labelledby=\"ccs-installation\"\u003e\n    \u003ch2 id=\"ccs-installation\"\u003eInstallation and support requirements\u003c\/h2\u003e\n\n    \u003cp\u003eCatnic CCS lintels must be suitably propped and laterally restrained during construction. To achieve the published loading figures, the lintel must be fully built into the brickwork or blockwork as specified by Catnic.\u003c\/p\u003e\n\n    \u003caside class=\"wbs-product-notice wbs-product-notice--important\"\u003e\n      \u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Provide suitable temporary propping and lateral restraint during construction. Do not apply loads beyond the manufacturer's published safe working load for the selected length and installation conditions.\u003c\/p\u003e\n    \u003c\/aside\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"wbs-product-section\" aria-labelledby=\"ccs-related\"\u003e\n    \u003ch2 id=\"ccs-related\"\u003eRelated single-leaf lintels\u003c\/h2\u003e\n\n    \u003cp\u003eFor a different profile, Wade also supplies the \u003ca href=\"https:\/\/www.wadebuildingsupplies.co.uk\/products\/catnic-ang-lintel-single-leaf-solid-wall-100mm\"\u003eCatnic ANG 100mm single-leaf angle lintel\u003c\/a\u003e.\u003c\/p\u003e\n\n    \u003cp\u003eBrowse our \u003ca href=\"https:\/\/www.wadebuildingsupplies.co.uk\/collections\/single-leaf-lintels\"\u003esingle-leaf lintel collection\u003c\/a\u003e for other available models and lengths.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"wbs-product-downloads\" aria-labelledby=\"ccs-downloads\"\u003e\n    \u003ch2 id=\"ccs-downloads\"\u003eTechnical downloads\u003c\/h2\u003e\n    \u003cul class=\"wbs-product-downloads-list\"\u003e\n      \u003cli\u003e\n        \u003ca href=\"https:\/\/catnic.com\/assets\/datasheets\/uk\/lintels\/ccs.pdf?v=1739350222\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCatnic CCS technical datasheet (PDF, opens in new tab)\u003c\/a\u003e\n      \u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/section\u003e\n\n  \u003caside class=\"wbs-product-cta\"\u003e\n    \u003cdiv class=\"wbs-product-cta__content\"\u003e\n      \u003ch2\u003eNeed help selecting a Catnic single-leaf lintel?\u003c\/h2\u003e\n      \u003cp\u003eWade's team can help you check the available lintel lengths and product specifications. Have your wall type, opening width and loading information ready when enquiring.\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"wbs-product-cta__action\"\u003e\n      \u003ca href=\"https:\/\/www.wadebuildingsupplies.co.uk\/pages\/contact-us\"\u003eContact Wade\u003c\/a\u003e\n    \u003c\/p\u003e\n  \u003c\/aside\u003e\n\n  \u003csection class=\"wbs-product-faq\" aria-labelledby=\"ccs-faq\"\u003e\n    \u003ch2 id=\"ccs-faq\"\u003eFrequently asked questions\u003c\/h2\u003e\n\n    \u003cdetails\u003e\n      \u003csummary\u003eWhat wall thickness is the Catnic CCS designed for?\u003c\/summary\u003e\n      \u003cp\u003eThe Catnic CCS is designed for 100–102mm single-leaf masonry construction. It is not a combined cavity-wall lintel.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary\u003eDoes the Catnic CCS lintel have an integral plaster key?\u003c\/summary\u003e\n      \u003cp\u003eNo. The Catnic CCS lintel does not have an integral plaster key.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary\u003eWhat is the safe working load of a Catnic CCS lintel?\u003c\/summary\u003e\n      \u003cp\u003eCCS lintels from 750mm to 1800mm have a published safe working load of 15kN. Lengths from 1950mm to 4800mm have a published safe working load of 20kN. These ratings are subject to Catnic's specified installation and loading conditions.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary\u003eDoes a Catnic CCS lintel require propping?\u003c\/summary\u003e\n      \u003cp\u003eYes. Catnic specifies that CCS lintels must be suitably propped and laterally restrained during construction.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails\u003e\n      \u003csummary\u003eHow much end bearing does a CCS lintel need?\u003c\/summary\u003e\n      \u003cp\u003eCatnic specifies nominal 150mm end bearings at each end. Check the structural opening, the required lintel length and the applicable loading requirements before installation.\u003c\/p\u003e\n    \u003c\/details\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n","brand":"Catnic","offers":[{"title":"750mm","offer_id":40215816306839,"sku":"CCS0750","price":35.0,"currency_code":"GBP","in_stock":true},{"title":"900mm","offer_id":40215816372375,"sku":"CCS0900","price":41.0,"currency_code":"GBP","in_stock":true},{"title":"1200mm","offer_id":40215816536215,"sku":"CCS1200","price":56.0,"currency_code":"GBP","in_stock":true},{"title":"1350mm","offer_id":45566640324854,"sku":"CCS1350","price":63.0,"currency_code":"GBP","in_stock":true},{"title":"1500mm","offer_id":40215816667287,"sku":"CCS1500","price":71.0,"currency_code":"GBP","in_stock":true},{"title":"1800mm","offer_id":40215816798359,"sku":"CCS1800","price":84.0,"currency_code":"GBP","in_stock":true},{"title":"2100mm","offer_id":40215816929431,"sku":"CCS2100","price":125.0,"currency_code":"GBP","in_stock":true},{"title":"2400mm","offer_id":40215817060503,"sku":"CCS2400","price":144.0,"currency_code":"GBP","in_stock":true},{"title":"2700mm","offer_id":40215817191575,"sku":"CCS2700","price":217.0,"currency_code":"GBP","in_stock":true},{"title":"3000mm","offer_id":40215817322647,"sku":"CCS3000","price":241.0,"currency_code":"GBP","in_stock":true},{"title":"3300mm","offer_id":40215817388183,"sku":"CCS3300","price":427.0,"currency_code":"GBP","in_stock":true},{"title":"3600mm","offer_id":40215817453719,"sku":"CCS3600","price":466.0,"currency_code":"GBP","in_stock":true},{"title":"3900mm","offer_id":40215817519255,"sku":"CCS3900","price":505.0,"currency_code":"GBP","in_stock":true},{"title":"4200mm","offer_id":40215817584791,"sku":"CCS4200","price":543.0,"currency_code":"GBP","in_stock":true},{"title":"4800mm","offer_id":40215817715863,"sku":"CCS4800","price":622.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0565\/7293\/6343\/files\/CCS-render.jpg?v=1712188390","url":"https:\/\/www.wadebuildingsupplies.co.uk\/products\/catnic-single-leaf-ccs-lintel-100mm","provider":"Wade Building Supplies","version":"1.0","type":"link"}